The ion exchange membrane for electrolysis is produced by the unique tape casting process with appropriate molecular weight and ion exchange capacity of perfluorosulfonic acid resin to form homogeneous membrane with uniform thickness,the Ion-Exchange Membrane has the characteristics of high tensile strength, isotropic, high electrical conductivity, good chemical properties, and so on.
The Principle of electrolysis water
Water reacts at the anode to form oxygen and positively charged hydrogen ions (protons).The electrons flow through an external circuit and the hydrogen ions selectively move across the PEM to the cathode.
At the cathode, hydrogen ions combine with electrons from the external circuit to form hydrogen gas.
Anode Reaction: 2H2O → O2 + 4H+ + 4e- C
athode Reaction: 4H+ + 4e- → 2H2
Technical Specifications(Reference Standard):
Physical and Other Properties |
Values |
Test Method |
|
|
|
Tensile Strength MD, max., MPa |
36 |
ASTM D882 |
Tensile Module, MPa |
410 |
ASTM D882 |
Elongation at break, % |
190 |
ASTM D882 |
Specific Gravity |
1.98 |
体积称重法 |
|
|
|
Other Properties |
Values |
Test Method |
Conductivity, S/cm |
0.10 |
GB/T 20042.3-2009 |
Acid capacity, meq/g |
1.0 |
GB/T 20042.3-2009 |
|
|
|
Hydrolytic Properties |
Values |
Test Method |
Water Content, % |
5.0±3.0 |
ASTMD570 |
Water Uptake, % |
50.0±5.0 |
ASTMD570 |
Thickness Change, |
|
ASTM D 756 |
Linear Expansion, |
|
ASTM D 756 |
1, Measurements taken with membrane conditioned to 23°C,50% RH.
2, Conductivity measurements at 23°C,100% RH.
3, A base titration procedure measures the equivalents of sulfonic acid in the polymer, and uses the measurement to calculate the acid capacity or equivalent weight of the membrane.
4, Water content of membrane conditioned to 23°C and 50% RH (dry weight basis).
5, Water uptake from dry membrane to conditioned in water at 100°C for 1hour (dry weight basis).
Thickness and Weight:
Thickness(μm) |
Weight(g/m2) |
127 |
250 |
183 |
360 |
254 |
500 |
Remarks:The thickness is approximate number, we do not assure absolute precision. Please contact with our salesman if special thickness is requested.
Packing:
Our Perfluorinated Ion-Exchange Membrane has sheet and continuous roll:Sheet material standard size:600mm*600mm;800mm*800mm
Continuous Roll: 800mm width and 680mm with continuous roll
We can also provide special customized size according to your requirement.
Standard packing is packaging the PIEM in plastic drum or bucket.
Electrodialysis Device for Lab Testing
Graphene Perfluorinated IEM SY-11GP
Perfluorinated IEM for Flow Battery
Ion Exchange Membrane for Fuel Cell
Perfluorinated IEM for Water Treatment
PTFE Enhanced Perfluorinated IEM
Perfluorinated IEM for Electrolysis
Hydrogen-rich Water Cup Membrane